Sign In | Join Free | My himfr.com
Home > Telecom Power System >

3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003)

Beijing Ding Ding Future Technology Co.Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003) from wholesalers
     
    Buy cheap 3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003) from wholesalers
    • Buy cheap 3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003) from wholesalers
    • Buy cheap 3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003) from wholesalers
    • Buy cheap 3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003) from wholesalers
    • Buy cheap 3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003) from wholesalers

    3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003)

    Ask Lasest Price
    Brand Name : Eltek
    Model Number : CTOR0201.003
    Certification : CE, UL
    Price : 1800 USD / 3500 USD
    Payment Terms : L/C, T/T
    Supply Ability : 500 sets per month
    Delivery Time : 8-10 weeks
    • Product Details
    • Company Profile

    3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003)

    3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003)


    Eltek Rectiverter Integrated Standalone System 3kVA 1phase 220 VDC (Part No.:CTOR0201.003 CTOR0201.006 )


    Applications :


    The rectiverter integrated standalone system can be used in application where

    1 230/115Vac backup is needed in parallel with the 220Vdc backup .


    The system can be integrated into an Eltek DC system and connected to the same controller as the 220Vdc systems


    It can also be used as a standalone system connected to any available, 220Vdc source.


    The total output power for both AC and DC output is limited to max 4kw, AC and DC output limits can be set according to the attached load.Where the limitation for AC load is set to max 3Kva.


    TELECOM-MOBILE/WIRELESS


    l LTE/4G/WiMAX

    l Distributed antenna system

    l Broadband

    l Radio base stations/cell sites

    l ·

    l RAILWAY & METRO INFRASTRUCTURE


    l Control & protection

    l Signaling

    l GSM-R

    l Safety Systems

    l ·

    l POWER UTILITIES


    l Control & protection

    l SCADA system


    Key Features :


    Compact design and simple installation

    Single phase 230 or 115VAC input and output

    l 48Vdc input and output

    l Up to 4 rectiverter modules

    l 8KW total AC+DC output

    l Max 6kVA AC output

    l Max 4KW/ 8KW DC output

    l 1 or 2 pole AC distribution options

    l 1 Pole DC distribution option

    l Built in transfer technology


    Techinical Data:


    Models / ordering information4 kW, 230 V2 kW, 115 V
    Part numberCTOR0201.003CTOR0201.006
    AC OUTPUT DATA
    Voltage (default) / (adjustable range)1)230 VAC / 200 - 240 VAC115 VAC / 100 - 127 VAC
    Frequency (default inverter mode)50 Hz (adaptive)60 Hz (adaptive)
    Frequency (set-able inverter mode)50Hz, 60Hz or last synced 50/60Hz (adaptive)
    Power maximum (continuous / overload (<15s) )2400 W (3000 VA) / 4000 VA1200 W (1500VA) / 2000 VA
    Current maximum (continuous / overload (<15s) )13ARMS / 17,4ARMS
    Current (maximum) Quick trip (20ms)64 A (6 x nominal)
    Hold up (Voltage dips) (before switching to battery)5 ms
    THD< 1.5 % at resistive load
    Output featuresFuse in L and N, Hot pluggable
    DC OUTPUT DATA
    Voltage (default) / (adjustable range)245 VDC / 194 - 290 VDC
    Power (maximum @nominal input)2400 W 2)1200 W 2)
    Current (maximum @nominal output VDC)11,1 A 2)5,5 A 2)
    Hold up time, maximum output power>10ms; VOUT > 95 VDC
    Output featuresShort circuit proof, Over voltage Shutdown, Bulk DC output connection to M6 bolt
    INPUT DATA
    AC Mains Input Voltage (single phase)185 - 275 VAC95 - 140 VAC
    AC Current (at nominal output voltage) (depending on module type)14-24 ARMS 4)
    Frequency (default: sync range)47-53 & 57-63 Hz57-63 & 47-53 Hz
    Frequency (set-able: sync range)47-53 Hz, 57-63 Hz or both (adaptive)
    Power Factor / THD> 0.99 at 50% load or more / < 3.5%
    DC Voltage nominal / extended range (no overload)3)204 - 290 VDC / 180 - 204 VDC
    DC Current (maximum)13,3 A / 18 A during overload (15s)6,4 A / 9 A during overload (15s)

    Input features

    Fuse in L and N, Hot pluggable, Varistor, Hot pluggable

    AC input individual screw terminals 6 mm2 for L, N & PE Bulk DC input connection to M6 bolt

    OTHER SPECIFICATION
    Support for connection to following controller (RJ45)Smartpack2, Smartpack S & Compack controllers
    Efficiency>96% (mains mode (AC/AC and AC/DC)), >94% (inverter mode (DC/AC))
    2 pole AC distribution (connection IEC 320-C13 sockets)3pc, 10A, OP characteristics (optional 4-8 A breaker with CS characteristics available)
    Protection ClassIP 20
    Operating temperature-40 to +55°C (+40 to +131°F), humidity 5 - 95% RH non-condensing
    Storage temperature-40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing
    Dimensions[WxDxH] / Weight482 x 395 x 44mm (1U) (19 x 17 x 1,8”) / 6kg (13 lbs)
    DESIGN STANDARDS
    Electrical safetyEN 60950-1, EN 62040-1
    EMC

    ETSI EN 300 386 V.1.6.1, FCC CFR 47 Part 15 EN 61000-6-1/-2/-4/-5

    EN62040-2 (Cat C1 emmisions, cat C2/C3 immunity)


    Environment

    ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3)

    Normal operating conditions as per IEC/EN 62040-3:2011 clause 4.2.

    Other operating conditions as per IEC 62040-3:2011 clause 4.3, must be advised 2011/65/EU (RoHS) & 2012/19/EU (WEEE)

    1) Output voltage ranges configured in factory and have individual keying in top chassis

    3) Reduced performance - no power boost and increased voltage THD on AC output.

    2) AC load has priority. Maximum available DC output power and current is dependent on instant AC

    load and AC input voltage; i.e maximum 1600W at full AC power and nominal input for 230VAC.

    4) If DC voltage is pulled below 194 V the input current may increase above this level


    3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003)

    3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003)


    Related Products:


    3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003)3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003)


    3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003)3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003)

    3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003)3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003)

    3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003)

    Solutions

    We provide a complete solutions including site survey, propose professional plan according to customer’s request ,technical support, and maintenance service for Telecommunication Companies in and out of China. We have a competent team and a network of trusted Partners around the world.


    FAQ :

    1. How do you control the quality?

    A:All products before the shipment are simulated usage scenarios, load and full load and current sharing test to ensure the quality of the product.


    2. What is your minimum order quantity?

    A:There is no minimum order quantity, and one can also be done. The only difference is the price and schedule.


    3. Can you introduce your company?

    A:I am very honored. I will send you the company’s introduction document later to give you a more comprehensive and direct introduction to our company’s information.


    4. What are the advantages of your company?

    A:Adequate inventory, and supply guarantee for the subsequent renewal of supply, flexible provided according to different to different needs of customers, providing different solutions.


    5. Can i send samples?Report it to me along with the price?

    A:You can send samples, the samples are subject to large pride, and the freight needs to be borne by you.


    6. How do your company deal with the problem on quality?

    A:Our company has been doing this industry for almost 10 years. It has already had a certain reputation. We will carefully analyze it. If it is indeed our quality problem, you can rest assured that it will do things according to the contract agreement and will never let you have any after the worries, our service team will be happy to serve you.


    7 What about the quality ?

    A:100% original with new package. we will test each item before posted to make sure each item with good quality.


    8 How many months for guarantee ?

    A: 1 year quality guarantee


    9 How to deal with any inferior -quality goods ?

    A: Goods can be post by with our charge of post fee for any bad quality products within guarantee time.


    Quality 3kVA 1phase 220VDC Telecom Power System Rectiverter Integrated Standalone (Part No.:CTOR0201.003) for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Beijing Ding Ding Future Technology Co.Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)